KOALA KARE PRODUCTS
KB200 HORIZONTAL WALL MOUNTED
BABY CHANGING STATION
KB200-00 CREAM
KB200-01 GREY
KB200-05 WHITE GRANITE
35
3
/
16
(894 mm)
19
11
/
16
(500 mm)
18
5
/
32
(461 mm)
KB200 TECHNICAL DATA SHEET
MATERIALS:
Injection-molded polypropylene with Microban® antimicrobial additive embedded into the bed
surface. Reinforced steel-on-steel hinge mechanism and metal mounting chassis with mounting
hardware included. Labelled usage instructions and safety messages in four languages.
Optional Braille label available. Contoured changing surface area is 450 sq. in (2903 sq. cm)
and comes complete with nylon safety strap and bag hooks. Dual cavity liner dispenser holds
approximately 50 KB150-99 bed liners.
OPERATION:
Concealed pneumatic cylinder and metal mounting chassis provides controlled, slow opening
and closing of bed. Polypropylene is easy to clean and resists odors and bacterial growth.
Complies with ASTM static load performance requirements when properly installed.
Warning: To ensure that the unit supports the intended loads, baby changing stations must be
properly installed according to the manufacturer’s instructions.
SPECIFICATION:
Baby changing station body shall be durable, injection-molded polypropylene. Design of unit
shall be surface-mounted. Unit shall be equipped with a pneumatic cylinder for controlled
opening and closing of bed. Bed shall be secured to metal mounting chassis with a concealed
steel-on-steel hinge. No hinge structure shall be exposed on interior or exterior surfaces. Unit
shall have mounting hardware included. Unit shall have Microban® antimicrobial embedded
into plastic material on the changing surface. Unit shall comply with ADA regulations when
properly installed. Bed shall have smooth concave changing area with a nylon safety strap
and two hooks for bags or purses. The design and manufacture of Koala products is intended
to be compliant with the 2010 ADA Standards for Accessible Design and the 2009 ICC A117.1,
Accessible and Usable Buildings and Facilities. Unit shall conform to ASTM F 2285-04 Standard
Safety Performance Specification for Diaper Changing Tables for Commercial Use, ANSI Z535.4
Product Safety Signs and Labels, EN 12221:2008, ASTM G22 Antibacterial standards or local
code if more stringent installation requirements are applicable for Barrier-Free accessibility.
Unit shall have a built-in Liner Dispenser for use with 3-ply chemical free biodegradable bed
liners, instructional graphics and safety messages in 4 languages. Optional Braille label is
available. Unit shall be backed by manufacturers 5-year limited warranty on materials and
workmanship and include a provision for replacement caused by vandalism. Unit shall be
manufactured in the U.S.A.
INSTALLATION:
To ensure proper installation and compliance to building codes, it is recommended that a qualified
person or carpenter perform the installation of the unit. The unit must be properly installed onto a
permanent wall that is capable of supporting significant weight and can accommodate the supplied
installation hardware. The Koala Baby Changing Station meets ADA regulations when properly installed.
Installer should account for the space that a unit occupies when in the down position and with the
caregiver (whether standing or seated) in front of the unit. Locate the unit so that paths of travel are
maintained around it when being used.
1. Remove changing station from the shipping container and check for any freight damage. If damage is
found, please call Koala Kare Products’ Customer Service at 888.733.3456. Remove “Installation Kit”
and “Operator Kit” from box. Please give “Operator Kit” to facility manager or operator. Box should
contain two pieces: the bed and metal mounting chassis and the wall mount liner dispenser. Identify
the best location for installing the unit.
2. Remove the bed and chassis from the box and select the wall area where the unit will be installed.
Make sure you have taken into consideration the operating clearance of 9½" (241 mm) on both sides
of the exposed chassis and 23 3/16" (589 mm) from wall surface when open.
For Wood Stud Wall- Measure from the floor 42¼" (1073 mm) on stud center and mark the wall. The
mounting holes are designed for 16" (406 mm) stud centers. Ensure the locations you have marked
for the mounting holes are level before drilling. Drill pilot holes for keyhole mounting using a 1/8"
regular drill bit. If the wall has wooden studs that are not on 16" (406 mm) centers, you will need
to use toggles to secure one side of the unit. The other side should be secured to the stud using
the screws provided. You must allow for space inside the wall for the toggles to turn. This will vary
depending on the toggles used.
For Masonry or Tile over Stud Wall- Use a 7/32" (5 mm) masonry drill bit for the pilot hole until you hit
the stud. Change bit to 1/8" (3 mm) regular drill bit.
For Metal Stud or Concrete Block- If the wall has metal studs or an underlying surface of concrete
block, you will need to use toggles to secure one side of the unit. The other side should be secured to
the stud using the screws provided. You must allow for space inside the wall for the toggles to turn.
This will vary depending on the toggles used.
3. Screw two of the mounting screws into the pilot holes leaving ¼" (6 mm) exposed to allow keyhole
slots to be easily mounted over the screw heads. Place chassis over screws. After securing the unit
using the keyhole slots, verify that the unit is level. Tighten top two screws so that they are flush with
the wall. Use the four lower holes as a guide to mark and drill pilot holes. Use remaining four screws
and four washers to complete installation of bed and metal mounting bracket. Insert washers over
lower four screws. All SIX screws and four washers must be mounted to the chassis.
4. Ensure liner dispenser is free from damage. Remove key, unlock, and open liner dispenser lid. This
will expose liner dispenser mounting holes. Line up dispenser mounting holes onto chassis and secure
with the four screws provided. Close and lock the liner dispenser door.
5. Clean work area and inspect unit to ensure it opens and closes smoothly. Give Operator Kit and key
to the facility operator.
Replacement Parts: For a list of replacement parts for this product (such as straps, shocks and labels),
please visit koalabear.com. Replacement parts and additional liners can be purchased from your local
distributor or direct from Koala at koalabear.com.
The illustrations and descriptions herein are applicable to production as of the date of this Technical
Data Sheet. The manufacturer reserves the right to, and does from time to time, make changes and
improvements in designs and dimensions without notice.
Koala Kare Products | 6982 S Quentin St. | Centennial, CO 80112 Toll Free: 888.733.3456 | 303.539.8300 | Fax: 303.539.8399
www.koalabear.com
P/N AB005 April 2023